Melt Flow Index, Melt Flow Rate testing to ASTM D1238 or ISO 1133 Standards
Scope:
Melt Flow Rate measures the rate of extrusion of thermoplastics through an orifice at a prescribed temperature and load. It provides a means of measuring flow of a melted material which can be used to differentiate grades as with polyethylene, or determine the extent of degradation of the plastic as a result of molding. Degraded materials would generally flow more as a result of reduced molecular weight, and could exhibit reduced physical properties. Typically, flow rates for a part and the resin it is molded from are determined, and then a percentage difference is calculated. Alternatively, comparisons between "good" parts and "bad" parts may be of value.
Test Procedure:
Approximately 7 grams of the material is loaded into the barrel of the melt flow apparatus, which has been heated to a temperature specified for the material. A weight specified for the material is applied to a plunger and the molten material is forced through the die. A timed extrudate is collected and weighed. Melt flow rate values are calculated in g/10 min.
Specimen size:
At least 14 grams of material
Data:
Flow rate = ( 600/t x weight of extrudate )
t = time of extrudate in seconds
melt flow rate = g/10 min.
**Please note that this test description is intentionally generic in nature and aimed at providing a descriptive summary to enhance test understanding. Standards can be obtained from appropriate standard authorities.
Polymers News and Events
LEARN how CircularAssure helps you to close the loop in the circular economy for plastics
Technical Talk: Circularity - Addressing Challenges in Material Development through Evaluation Programs
BROCHURE: Injection Moulding Test Specimen Production Catalogue
ARTICLE: Processability and evaluation programmes for recycled plastic materials
ARTICLE: Adhesives Quality Assurance Testing Programs
ARTICLE: Enabling Polymer Non-Wovens Development
CASE STUDY: Polymer Surface Contamination Resolution
CASE STUDY: Elastomer Seal Material Failure
CASE STUDY: Polymer Failure - Distribution and Dispersion of Fillers